Side Pull Prevention
Side pull can cause violent and hazardous load swing and hoist components such as the rope guide or drum might get damaged, or in the worst case load ropes may snap. Preventing side pull will help make your operations faster and safer.
Compatibility and restrictions
- Compatible for all types and makes of lifting equipment, but mechanical fixing may vary
- Recommended maximum height of lift (HoL) 10 meters (if more than this, the measurement becomes inaccurate)
- Does not support CAN-bus connection, inclinometer works only for hard-wired equipment
- The wire rope diameter is between 5 mm-28 mm
- Variable packages based on control voltage (48V, 115V or 230V)
- The dead end of the wire rope anchors to the trolley, not the drum
- The winch has a cross bar, or similar structure, to mount the induction sensor near the drum face
-
Side pull prevention retrofit package for 48V control voltage and 17 - 19 mm rope diameter.
See product page for availability
-
Side pull prevention retrofit package for 115V control voltage and 26 - 28 mm rope diameter.
See product page for availability
-
Side pull prevention retrofit package for 115V control voltage and 23 - 25 mm rope diameter.
See product page for availability
-
Side pull prevention retrofit package for 115V control voltage and 20 - 22 mm rope diameter.
See product page for availability
-
Side pull prevention retrofit package for 115V control voltage and 5,0 - 6,5 mm rope diameter.
See product page for availability
-
Side pull prevention retrofit package for 115V control voltage and 17 - 19 mm rope diameter.
See product page for availability
-
Side pull prevention retrofit package for 48V control voltage and 23 - 25 mm rope diameter.
See product page for availability
-
Side pull prevention retrofit package for 115V control voltage and 8,5 - 10,0 mm rope diameter.
See product page for availability
-
Side pull prevention retrofit package for 230V control voltage and 12,5 - 14,0 mm rope diameter.
See product page for availability
-
Side pull prevention retrofit package for 230V control voltage and 5,0 - 6,5 mm rope diameter.
See product page for availability
-
Side pull prevention retrofit package for 230V control voltage and 15,0 - 16,5 mm rope diameter.
See product page for availability
-
Side pull prevention retrofit package for 230V control voltage and 20 - 22 mm rope diameter.
See product page for availability
-
Side pull prevention retrofit package for 230V control voltage and 7,0 - 8,0 mm rope diameter.
See product page for availability
-
Side pull prevention retrofit package for 48V control voltage and 10,5 - 12,0 mm rope diameter.
See product page for availability
-
Side pull prevention retrofit package for 230V control voltage and 23 - 25 mm rope diameter.